In Stock
RH/Temp Smart Control, External probe: 2 Equipments
☆☆☆☆☆
$410.25
How a Two Outlet Temperature and Humidity Controller Divides the Work
One outlet for the condition you are heating or cooling, one for the condition you are wetting or drying. That split is the whole design, and it is why this unit replaces two separate single task controllers.
Purchase directly from Growers HouseHow a Two Outlet Temperature and Humidity Controller Divides the Work
One outlet for the condition you are heating or cooling, one for the condition you are wetting or drying. That split is the whole design, and it is why this unit replaces two separate single task controllers. Each outlet has its own target, so a heater and a dehumidifier stop fighting each other for the same reading. It runs cooling, heating, humidifying, dehumidifying, or cooling and dehumidifying together. Electrically it is 120 volts at 15 A, with a total load ceiling of 2 HP across both outlets. That ceiling is the number to check first, because two large machines will exceed it long before the outlets do. Day and night detection is built in, and each period carries its own pair of set points. Operation priority is adjustable, which decides what happens when both conditions call at once. So is the shutdown delay, which is what keeps a compressor from restarting into its own back pressure.
Why the External Probe Placement Decides Your Readings
An external probe on a lead is the reason this unit reads the room instead of reading itself. A controller with the sensor inside its own case sits on a wall warmed by whatever is behind it. Accuracy is plus or minus one degree Celsius on temperature and plus or minus 3.5 percent on relative humidity. Those tolerances only hold where the probe hangs in moving air at canopy height. Put it in the middle of the space, out of the discharge of anything it switches, and clear of the lights. A probe in a dehumidifier's exhaust will hold the room far wetter than the display claims. The four equipment version of this controller is a separate unit. Anyone who needs to add carbon dioxide control needs a different model again. This one does two jobs properly rather than four approximately.
Key Features
Outlets: Two, one for temperature equipment and one for humidity
Modes: Cooling, heating, humidifying, drying, or cooling with drying
Probes: Both readings from external sensors on a lead
Temperature accuracy: Plus or minus one degree Celsius
Humidity accuracy: Plus or minus 3.5 percent relative humidity
Electrical: 120 volts, 15 A, 2 HP total load
Day and night: Detected automatically, with its own set points each
Adjustable: Operation priority and shutdown delay
Bigger version: A four equipment model exists as a separate unit
Technical Specifications
Specification
Value
SKU
NBIGS110S
Model
iGS-110
Brand
Intelligent Growing Systems
Type
Combined temperature and relative humidity controller
Equipment controlled
Two, on separate outlets
Modes
Cooling, heating, humidifying, dehumidifying, or cooling plus drying
Temperature sensor
External probe, accuracy plus or minus 1 degree Celsius
Humidity sensor
External probe, accuracy plus or minus 3.5 percent
Voltage
120 V
Current
15 A
Total load
2 HP
Day and night control
Automatic detection, separate set points each
Adjustable settings
Operation priority and shutdown delay
Larger model
The four equipment version is a separate product