Honeywell H6062A1000 HumidiPRO Humidistat and Dehumidistat, 24VAC
☆☆☆☆☆
$179.00
How the Honeywell HumidiPRO Wires In
This is an HVAC control rather than a plug-in timer. It takes 24 volts alternating current from the furnace or air handler on the C and R terminals. Two U terminals drive the humidifier or the dehumidifier.
Purchase directly from Growers HouseHow the Honeywell HumidiPRO Wires In
This is an HVAC control rather than a plug-in timer. It takes 24 volts alternating current from the furnace or air handler on the C and R terminals. Two U terminals drive the humidifier or the dehumidifier. Two S terminals take the outdoor sensor when one is fitted. The head mounts in a duct or remotely on a wall, whichever suits the room. Setpoints are held separately for each direction, so adding moisture and removing it do not share a number. Ambient limits run from 32 to 120 degrees Fahrenheit, at 5 to 90 percent relative humidity, non-condensing. The display is digital with a backlight button on the face. Nothing here plugs into a socket. Sort out the low-voltage supply before anything gets mounted.
What a Digital Humidistat Gives You Over a Dial
A dial has one setpoint and a mechanical element sitting behind it. This holds separate ranges for adding moisture and for taking it away, each adjustable from ten to ninety percent. Wire in the C7089 outdoor sensor and it runs automatically, walking the indoor setpoint down as it gets colder outside. That is window condensation protection, worked from a frost index table rather than guesswork. Leave the sensor off and it stays in manual mode, holding whatever number you set. Automatic behaviour is usually the wrong choice in a grow room. A curve tuned to house windows is not a curve tuned to a canopy. Manual mode with a tight differential is what most rooms actually want. The honest limit is the installation, because this belongs to a ducted system and needs a transformer. A grower without ducted air is better served by an outlet controller.
Key Features
Two directions: Humidification and dehumidification from one control head
Range: Each direction adjustable across ten to ninety percent
Power: 24VAC constant from a furnace or air handler, not a wall socket
Terminals: C and R for power, two U for equipment, two S for the sensor
Automatic mode: Steps the setpoint down as outdoor temperature falls
Manual mode: Holds a fixed relative humidity with no outdoor sensor
Mounting: Duct mounted or remotely wall mounted
Display: Digital readout with a backlight button
Technical Specifications
Specification
Value
Model
H6062A1000, HumidiPRO
Function
Humidistat and dehumidistat
Humidify range
10 to 90 percent
Dehumidify range
10 to 90 percent
Power
24 VAC constant
Terminals
C, R, 2 x U, 2 x S
Outdoor sensor
C7089, drives automatic mode
Ambient temperature
32 to 120 F (0 to 48.9 C)
Ambient humidity
5 to 90 percent, non-condensing
Mounting
Duct or remote wall
Display
Digital, backlit