Home›Cannabis Grow›Grow Equipment›Hanna 1382 ppm Calibration Solution | HI7032L, 500 mL TDS Standard

In Stock
Hanna 1382 ppm Calibration Solution | HI7032L, 500 mL TDS Standard
☆☆☆☆☆
Department: Cannabis Grow
$18.99
When to Reach for a 1382 ppm Calibration Solution
One value, 1382 mg/L, in a 500 mL bottle. It is prepared against NIST 2202 potassium chloride, using certified balances, Class A glassware and certified thermometers. That chain is what makes the number on the label mean anything at all.
Purchase directly from Growers HouseWhen to Reach for a 1382 ppm Calibration Solution
One value, 1382 mg/L, in a 500 mL bottle. It is prepared against NIST 2202 potassium chloride, using certified balances, Class A glassware and certified thermometers. That chain is what makes the number on the label mean anything at all. The bottle is air tight under a tamper-proof seal, with the lot number and expiry printed on the label. Unopened it carries five years from manufacture.
Picking the Right Bottle for TDS Meter Calibration
Hanna testers that read both scales take a single calibration point, and they will accept either 1413 µS/cm or this bottle. Which one you open depends on the side you are calibrating. If the meter is showing microsiemens, reach for the 1413 standard. If it is showing ppm, reach for this one. Let the bottle warm to room temperature before the probe goes in. Then read the chart on the label for the temperature you are actually working at. One limit worth naming plainly. This is one value on one scale. A meter set to the 4-4-2 or 700 factor will not land on the label figure, and Hanna makes a separate standard for that case.
Key Features
1382 mg/L TDS: The ppm-side calibration point that Hanna combo testers recognise.
Pairs with the 1413 standard: One bottle for microsiemens, this one for ppm. Same meters, different scale.
NIST 2202 traceable KCl: Prepared with certified balances, Class A glassware and certified thermometers.
500 mL bottle: Enough for a season of routine checks between feeds.
Temperature chart on the label: The real conductivity figure at the temperature you are standing in.
Lot and expiry marked: Air tight under a tamper-proof seal, five years from manufacture unopened.
One scale, by design: Meters on the 4-4-2 or 700 factor need a different standard.
Technical Specifications
Specification
Value
Brand
Hanna Instruments
Part Number
HI7032L
Type
TDS standard solution
TDS Value
1382 mg/L, 1382 ppm
Volume
500 mL, about 16.9 fl oz
Composition
Potassium chloride in deionised water
Traceability
Prepared against NIST 2202 SRM potassium chloride
Preparation
Certified balances, Class A glassware, certified thermometers
Label
Temperature chart, lot number and expiry date
Packaging
Air-tight bottle, tamper-proof seal
Shelf Life
5 years from manufacture, unopened
Paired Standard
HI7031L at 1413 uS/cm, for the conductivity scale
Other Scale
HI70442L at 1500 mg/L, for 4-4-2 scale meters
Other Sizes
HI7032M 230 mL, HI7032/1L 1 L, HI70032P 25 x 20 mL packets
Use
Calibrating TDS and PPM meters on the matching scale






