Home›Cannabis Grow›Grow Equipment›DAB® JETCOM 132 M Pump with Mascontrol | 1.36 HP, 115V/230V, 31.9 psi Cut-In

In Stock
DAB® JETCOM 132 M Pump with Mascontrol | 1.36 HP, 115V/230V, 31.9 psi Cut-In
☆☆☆☆☆
Department: Cannabis Grow
$835.10
The JETCOM 132 Mascontrol Pump Runs Without a Pressure Tank
Most pressure setups need a tank, a switch, and somewhere to put both. This one replaces all three with a controller threaded onto the discharge port.
Purchase directly from Growers HouseThe JETCOM 132 Mascontrol Pump Runs Without a Pressure Tank
Most pressure setups need a tank, a switch, and somewhere to put both. This one replaces all three with a controller threaded onto the discharge port. The MC/USA 1 watches pressure and flow, starting the pump when pressure falls below 31.9 psi. It shuts the pump down roughly 8 seconds after flow stops. Anything over 0.21 gpm is enough to keep it running. Underneath sits the same self-priming hydraulic end: 1.36 HP, 2.6 to 21 gpm, 158 ft of head and 26 ft of suction lift. The controller is rated to 15 gpm, so that is the practical ceiling on this pairing. Run-dry protection cuts power when the suction line loses water. That is the failure that kills a jet pump fastest.
Wiring and Plumbing a Constant Pressure Water Pump Correctly
Wire it for 230V if the choice is yours. The controller is rated 16 FLA at 115V and this pump draws 14.7 A on that leg. That leaves under an amp and a half of headroom. On 230V the same pump pulls 7.52 A against a 20 FLA rating, a far more comfortable margin. Mount the pump horizontally, and mount the controller on a vertical riser with its electronics box level. A controller cannot compensate for a suction leak; it will retry, fail to build pressure, and lock out. The controller body is reinforced polyamide with a stainless steel flow valve and an EPDM diaphragm. Its NEMA 12 enclosure tolerates a damp pump corner. Two limits are worth knowing. A controller-driven pump starts and stops on demand, so it is the wrong choice where you want the pump held on by a timer. And on a system with small persistent leaks it will cycle on every drip, where a small pressure tank would have absorbed them.
Key Features
MC/USA 1 Controller: Starts the pump at 31.9 psi and stops it about 8 seconds after flow ends, with no tank or switch to mount.
Run-Dry Protection: Cuts power when the suction line loses prime, before the mechanical seal cooks itself.
115V/230V Dual Voltage: Runs on either supply, though 230V leaves far more current headroom against the controller rating.
Self-Priming Hydraulic End: Draws from 26 ft (8 m) down and clears air from the suction line without hand-priming.
Technopolymer Wet End: Body, impeller, diffuser and Venturi resist nutrient solution that pits cast-iron over a season.
NEMA 12 Controller Housing: Reinforced polyamide, AISI 304 flow valve and EPDM diaphragm hold up in humid pump rooms.
Technical Specifications
Specification
Value
Pump Model
JETCOM 132 M
Controller
DAB MASCONTROL MC/USA 1
Controller Cut-In Pressure
31.9 psi
Controller Max Pressure
145 psi
Controller Max Flow
15 gpm (1 in version)
Controller Current Rating
16 FLA at 115V / 20 FLA at 230V
Controller Mounting
Vertical column, electronics box level
Motor Rating
1.36 HP (1 kW)
Power Supply
115V / 230V single phase, 60 Hz
Pump Current Draw
14.7 A at 115V / 7.52 A at 230V
Pump Flow Range
2.6 to 21 gpm (10–80 L/min)
Maximum Head
158 ft (48.3 m)
Pump Max Working Pressure
87 psi (6 bar)
Maximum Suction Lift
26 ft (8 m)
Pump Suction / Discharge
1 in NPT / 1 in NPT
Pump Net Weight
23 lb (10.5 kg)
Liquid Temperature
32°F to 104°F (0°C to 40°C)
Motor Protection
IP 44 (IP 55 terminal board)
Insulation Class
F
Pump Body, Impeller, Diffuser, Venturi
Technopolymer
Controller Body / Valve / Diaphragm
PA6GF30 polyamide / AISI 304 / EPDM
Controller Enclosure
NEMA 12
Liquid Requirements
Clean water, free of solids or abrasives